Polyurea Flooring & Joint Repair
Fast-cure polyurea and structural joint repair. Every floor starts with diamond grinding, never acid etching. Coating makers state the surface profile they need on the ICRI CSP scale, 1 nearly flat to 10 very rough (ICRI 310.2R-2013).
Why Polyurea Flooring & Joint Repair
Polyurea cures in a fraction of the time of epoxy and stays flexible in temperature swings. Paired with structural joint repair to stop spalling and protect equipment and forklifts.
- Same-day return to service
- Flexible in freeze/thaw
- UV-stable, no ambering
- Structural joint & crack repair

Polyurea Flooring & Joint Repair
Does your floor have to control static?
Polyurea handles the traffic and the freeze and thaw. If the same space also has to control static, that is a different build with a conductive layer tied into building ground.
Conductive
less than 1.0 x 10⁶ ohms
Measured to ANSI/ESD STM7.1.
Static dissipative
1.0 x 10⁶ up to less than 1.0 x 10⁹ ohms
Measured to ANSI/ESD STM7.1.
And the part people miss
less than 100 volts peak
Since 2014 there is a walking test too, ANSI/ESD STM97.2. A floor can hit the resistance number and still fail on this one.
Ready For Your Polyurea Flooring & Joint Repair Quote?
Send us your details and we'll respond within 24 hours with a straight, written estimate.
- Free, no-obligation written quote
- Locally owned & operated
- Premium materials, precision install
- Diamond-ground prep on every floor